How to Fill Out the Ohio EPA Hazardous Waste Generator Report (Biennial Hazardous Waste Report): A Line-by-Line Guide + FAQs

The Ohio EPA Hazardous Waste Generator Report, officially the Biennial Hazardous Waste Report, is the filing that every large quantity generator (LQG) in Ohio must submit to the Ohio EPA Division of Environmental Response and Revitalization to report how much hazardous waste it made, managed, and shipped during the prior year. You file it using Ohio EPA forms 9027 (GM Form), 9028 (related management forms), and 9029 (Site Identification Form), and it is due by March 1 of each even-numbered year, as set by Ohio Administrative Code 3745-52-41.

This guide uses the current Ohio EPA reporting forms and the December 2023 Instruction Booklet revision. The report covers federal Resource Conservation and Recovery Act (RCRA) requirements, so a single Ohio filing satisfies both your state and federal duties. Each year, thousands of Ohio LQGs file this report, and a single wrong waste code or EPA ID number is one of the most common reasons a report gets flagged for correction.

Here is what you will learn in this guide:

  • 📋 Who must file the report and which of the five Ohio forms apply to your site
  • 🗂️ Every document and number to gather before you open the forms
  • ✏️ A line-by-line walkthrough of the Site ID, GM, OI, WR, and PS Forms with sample entries
  • 🚚 Three full filing examples for a manufacturer, a one-time episodic generator, and a consultant
  • ⚠️ The mistakes that trigger a compliance flag and how to avoid every one of them

What the Report Is and Who Must File It

The Biennial Hazardous Waste Report is Ohio’s version of the federal RCRA biennial report, and it collects details about the generation, management, and final disposition of hazardous waste at your site. The legal authority comes from Sections 3002 and 3004 of RCRA, as amended by the Hazardous and Solid Waste Amendments of 1984, and it is carried into Ohio law through Ohio Admin. Code 3745-52-41. The plain meaning of this rule is simple: if you made a lot of hazardous waste in a reporting year, the state wants a full accounting of it.

You must file if your site was a large quantity generator in at least one month of an odd-numbered calendar year and did not opt into the episodic generator rules. A site is an LQG in any month it generates more than 1,000 kg (2,200 pounds) of non-acute hazardous waste, or more than 1 kg (2.2 pounds) of acute hazardous waste. You also must file if your site is a treatment, storage, or disposal facility (TSDF), a recycler of hazardous waste, or a reverse distributor of pharmaceuticals, as listed in the Ohio EPA Instruction Booklet.

The consequence of ignoring this rule is steep. If federal RCRAInfo lists your site as an LQG and you do not file, you appear out of compliance with both the report requirement and the every-two-year re-notification requirement under OAC 3745-52-18, which can draw an enforcement action and penalties. A common misconception is that small quantity generators (SQGs) and very small quantity generators (VSQGs) must always file. They do not, unless a one-time event pushed them over the 2,200-pound LQG threshold in a month and they did not opt into the episodic rules.

The agencies that interact with this report all play a role. Ohio EPA’s Division of Environmental Response and Revitalization (DERR) receives and stores your data, then forwards it to U.S. EPA, so you never file twice. The U.S. EPA maintains the national RCRAInfo database, which both agencies use to track your generator status and verify that your report was filed.

Before You Start: Documents and Information You Need

Pull your records together before you open a single form, because the report asks for exact quantities and codes that you cannot guess. Gathering everything first keeps your filing accurate and saves you from a mid-form scramble. The Ohio EPA Instruction Booklet lists the source records you should consult, and the checklist below expands on them.

  • Your 12-character EPA ID number. This is the unique identifier for your site, and every form links to your record through it; a wrong digit can attach your data to the wrong site or create a duplicate record.
  • All hazardous waste manifests for the reporting year. These show what you shipped, when, to whom, and in what quantity, and they are the backbone of the GM and OI Forms.
  • Records of quantities generated and accumulated. You report total quantity generated, so you need monthly logs; missing logs lead to undercounting and an inaccurate generator status.
  • Laboratory analyses of your wastes. These confirm the federal RCRA waste codes that must appear on each GM Form; without them you risk using the wrong code or reporting a non-RCRA waste.
  • Contracts and agreements with off-site TSD facilities. These give you the receiving facility names, EPA ID numbers, and management methods you need for the OI Form.
  • Permits for any on-site waste management systems. On-site TSDFs report treatment and storage data, and the permit confirms what systems operated during the year.
  • Your primary and secondary NAICS codes. Section 6 of the Site ID Form needs the 2022 NAICS code, so look it up at the U.S. Census Bureau before you start.
  • The name and title of your Responsible Official. This person signs the certification, and if they are unavailable at filing time, your report sits unsigned and unsubmitted past the deadline.
  • An OH|ID and eBusiness Center account with a PIN. Electronic filing requires these, and setting up a PIN can take days, so do not leave it to the last week of February.

Where to Get the Forms and How to Access Them

You get the forms two ways, and Ohio EPA strongly prefers the electronic route. The official forms and year-specific instructions live on DERR’s Hazardous Waste Report webpage, where you can also find the EPA waste code list and a national list of receiving facilities. The five forms are the Site Identification (Site ID) Form (EPA 9029), the GM Form for waste generated and managed, the OI Form for off-site transporters and receiving facilities, the WR Form for waste received from off-site, and the PS Form for commercial process systems.

The electronic system, called eDRUMS, runs inside Ohio EPA’s eBusiness Center and works in Chrome or Microsoft Edge with no software to download. To use it, you first create an account at the OH|ID portal, then log in to the eBusiness Center and request that DERR associate you with your facility. The Responsible Official (RO) or a Delegated Responsible Official (DRO) needs a PIN to certify the report, while a preparer, including an outside consultant, only needs an eBusiness Center account and a delegation.

The plain-English benefit of eDRUMS is fewer errors and faster filing. It pre-populates receiving facility and transporter EPA ID numbers from a pick list, auto-builds the OI Form from your GM Form entries, and lets you copy last cycle’s report as a starting point. If you ignore the electronic option and file on paper, you keep the work but lose the built-in validation, which raises your odds that Ohio EPA contacts you about an error. A common misconception is that you can fax the report; you cannot, because a fax lacks the original wet-ink signature the state requires on paper filings.

Step-by-Step: How to Fill Out the Ohio Biennial Hazardous Waste Report Line by Line

The report is built from five forms, and the order below follows the order Ohio EPA wants you to complete them. Every site files the Site ID Form and at least one GM Form, and you add the OI, WR, and PS Forms based on what your site did during the year. Use the exact field names and section numbers printed on each form, and write sample entries exactly as they appear on the page.

Site ID Form (EPA 9029), Section 1: Reason for Submittal

This section asks why you are sending the form, and for the report you always pick the same reason. Place an “X” in the box that reads “As a component of the Hazardous Waste Report,” then write the calendar year the report covers in the blank provided. For the cycle due March 1, 2026, Maria Lopez, the environmental manager at Buckeye Metal Finishing, writes 2025 in the year blank because the report covers 2025 activity.

An edge case trips people up here: the year you enter is the reporting year, not the year you are filing. If your site is filing in 2026, you still write 2025 because that is the year the waste activity happened. The most common mistake is entering the filing year, which makes your data land in the wrong reporting period and can look like a missed report. A widespread misconception is that this box is optional formatting; it is not, because Ohio EPA’s database keys your record to the reporting year you enter here.

Site ID Form, Section 2: Site EPA ID Number

This field asks for the unique 12-character EPA Identification Number assigned to your physical site. Enter all 12 characters with no spaces, and confirm them against your RCRAInfo record before you write them. Maria enters OHD000123456 for the Buckeye Metal Finishing plant.

The nuance is that the EPA ID belongs to the site location, not to your company; a business with three plants has three different EPA IDs. The most common mistake is transposing two characters, which links your waste data to a different site and creates a phantom compliance problem at both locations. The misconception that the EPA ID is the same as a state license or a tax ID is false, and using the wrong number is one of the fastest ways to get your report rejected.

Site ID Form, Sections 3 and 4: Site Name and Location

Section 3 asks for the legal and common name of your site, and Section 4 asks for the physical street address. Enter the full public or commercial name that appears on your invoices and signs, then give the actual street location. Maria writes Buckeye Metal Finishing, Inc. in Section 3 and 4820 Industrial Parkway, Columbus, OH 43219 in Section 4.

The key rule is that Section 4 must be a physical address, never a P.O. Box or rural route. The most common mistake is dropping a mailing address here, which the state cannot use to locate or inspect the site. A frequent misconception is that the location and mailing addresses must match; they do not, and you list the mailing address elsewhere on the form.

Site ID Form, Section 6: NAICS Code(s)

This section asks for the industry classification code that describes what your site does. Box A is mandatory and must hold your primary 5- or 6-digit 2022 NAICS code, while Boxes B through D are optional for additional codes. Maria enters 332813 in Box A for electroplating and metal finishing.

Use the most specific six-digit code you can find at the U.S. Census Bureau, and never enter a code of four digits or fewer because it is too general. The common mistake is reusing an outdated NAICS code from an old filing, which can misclassify your industry in state data. The misconception that any close code will do is risky, since the code helps the state and U.S. EPA group and analyze waste by industry sector.

Site ID Form, Section 7: Site Contact Person

This field asks who Ohio EPA should call about the report. Enter the name, title, business phone, e-mail, fax number, and mailing address of the person who can answer questions. Maria enters her own name, Environmental Manager, her direct line, and her e-mail.

E-mail and fax are optional, but providing an e-mail gives the state a faster way to reach you about an error. The common mistake is listing a general front-desk number, which delays the state when it needs a quick clarification and can push your correction past a deadline. The misconception that the contact must be the same person who signs the report is false; the contact and the certifier can be two different people.

Site ID Form, Section 8: Legal Owner and Operator

This section asks who owns and who operates the site, including the owner of the building and land. Enter the legal owner’s name, the date they became owner, the owner type, and a full address, then do the same for the operator. Maria lists Buckeye Holdings LLC as owner and writes same as owner for the operator because one entity does both.

If you are unsure of the exact date someone became owner, the instructions allow an educated guess for the year, month, and day. The common mistake is leaving this blank after an ownership change, which leaves the state with stale records and can complicate enforcement. A misconception is that “operator” means the plant manager; it means the legal entity that controls the site, usually a company name.

Site ID Form, Section 9: Generator Status (Box A, Items 1 and 2)

This is the section filers get wrong most, because it asks for two different generator statuses. Item 9.A.1 asks your current generator status as of the certification date, and Item 9.A.2 asks your generator status for the reporting year. Maria marks LQG in both because Buckeye was a large quantity generator in 2025 and still is in 2026.

These two answers can differ on purpose. A site that hit LQG levels only once because of a one-time cleanup might mark LQG in 9.A.2 for the reporting year but SQG or VSQG in 9.A.1 for its current status. The common mistake is marking the same status in both boxes by reflex, which can misstate your current standing in RCRAInfo. The misconception that “shipment equals generation” is wrong; generator status is based on how much waste you produce in a calendar month, not when you ship it.

Site ID Form, Section 12: Certification

This block asks an authorized official to swear the report is true. The signer reads the certification statement, then signs and dates it, either with a wet-ink signature on paper or with a PIN in eDRUMS. David Chen, a corporate vice president at Buckeye Holdings, signs as the Responsible Official.

Under OAC 3745-50-42, only a responsible corporate officer, a general partner or proprietor, a principal executive officer or ranking elected official, or a duly authorized written representative may sign. The most common mistake is letting a preparer or consultant sign without written authorization, which makes the certification invalid and the report incomplete. The misconception that any manager can sign is false, and an unsigned or wrongly signed report is treated as not filed.

GM Form (EPA 9027), Section 1: Waste Description and Codes

The GM Form is the heart of the report, and you file a separate GM Form for every distinct RCRA hazardous waste. Section 1 asks you to describe the waste and list its federal RCRA waste codes. Maria describes one stream as spent electroplating solution and enters code D008 for lead.

Use only federally recognized RCRA waste codes from the EPA waste code list; state-only wastes from other states and unmixed PCBs or asbestos do not belong here. The common mistake is reporting a waste just because it was manifested, even though not every manifested material carries RCRA codes. The misconception that a manifest alone qualifies a waste for the report is wrong; the waste must have federal RCRA codes to be listed.

GM Form, Section 2: Quantity Generated (Box B)

This section asks how much of this waste you generated during the reporting year. Enter the total quantity generated in Box B, using the unit of measure and density the form requires. Maria reports 6,400 pounds of spent electroplating solution generated in 2025.

A key nuance handles waste you made but had not shipped by year-end: report the full quantity generated in Section 2, Box B, then list only the shipped portion in Section 3, and the difference shows what stayed on-site. The common mistake is reporting only what you shipped, which undercounts generation and can misstate your LQG status. The misconception that on-hand waste does not count is false; you count it as generated in the year you made it.

GM Form, Section 3: On-Site and Off-Site Management

This section asks how the waste was managed, including the management method code and the EPA ID of the receiving facility for shipped waste. Enter the source code, the waste form code, the management method code, and the receiving facility’s EPA ID. Maria enters management method code H040 for incineration and the EPA ID of the off-site incinerator.

Note the 2023 code changes: code H135 was retired and replaced by H136 for discharge to a sewer or POTW with prior storage and H137 for NPDES discharge with prior storage. The common mistake is using a retired code like H135, which fails validation and forces a correction. The misconception that any disposal code is interchangeable is false; the code must match how the waste was actually handled.

OI Form: Off-Site Transporter and Receiving Facility Information

This form asks you to list the transporters and receiving facilities that handled your shipped waste. You file an OI Form when any RCRA hazardous waste left your site for treatment, storage, or disposal, listing each facility and transporter by name and EPA ID. Maria lists Clean Earth Environmental and its transporter with their EPA IDs.

Each OI Form holds up to four facilities or transporters, and one OI Form serves all your GM Forms because the data links through EPA ID numbers, not through a single GM Form. The common mistake is filing a separate OI Form for every GM Form, which creates redundant entries; the bigger danger is a wrong EPA ID, which breaks the link between forms. The misconception that you need one OI Form per waste stream is false, so accuracy on the EPA IDs matters far more than volume.

WR Form: Waste Received from Off-Site

This form applies only if your site received RCRA hazardous waste from off-site and managed it on-site during the reporting year. Enter the customer, the waste, the quantity received, and how you managed it. A commercial TSDF like Clean Earth Environmental files a WR Form for each customer whose waste it accepted.

If you claim trade secret protection for customer identity, you submit both a full copy and a public copy, because waste identification details stay public even when customer names are withheld. The common mistake is a generator filing a WR Form when it never received outside waste, which adds forms that do not apply. The misconception that every filer needs a WR Form is false; most generators never touch this form.

PS Form: Commercial Process Systems

This form is requested from commercial facilities that receive waste from off-site, and it lists the influent quantity for each treatment, disposal, or recycling (TDR) process system that ran during the year. Enter each process system’s type code and the influent quantity it handled. A commercial recycler reports the influent into each recycling system it operated.

The nuance is that you need one PS Form for each TDR system type code listed on your WR Forms, so the two forms must line up. The common mistake is a mismatch between WR and PS Forms, which the submission checklist specifically flags. The misconception that generators must file a PS Form is false; this form is only for commercial TDR facilities.

Three Filled-Out Examples Using Real Scenarios

These three scenarios follow named filers through the report from start to finish, showing what each enters in the major fields. They cover the most common filer types: a steady large quantity generator, a one-time episodic generator, and a consultant filing for a client.

Scenario 1: Maria Lopez, environmental manager at an LQG metal finisher shipping waste off-site

Form Section What Maria Enters
Site ID Section 1, Reason for Submittal “X” in “As a component of the Hazardous Waste Report,” year 2025
Site ID Section 2, EPA ID Number OHD000123456
Site ID Section 3, Site Name Buckeye Metal Finishing, Inc.
Site ID Section 6, NAICS Box A 332813
Site ID Section 9.A.1 / 9.A.2, Generator Status LQG current and LQG for reporting year
GM Form Section 1, Waste and Codes Spent electroplating solution, code D008
GM Form Section 2, Box B, Quantity Generated 6,400 pounds
GM Form Section 3, Management Method Code H040, off-site incinerator EPA ID
OI Form, Receiving Facility Clean Earth Environmental with EPA ID and transporter
Site ID Section 12, Certification Signed by David Chen, corporate VP

Scenario 2: Marcus Reed, plant owner who triggered the episodic 2,200-pound threshold once

Form Section What Marcus Enters
Site ID Section 1, Reason for Submittal “X” in report box, year 2025
Site ID Section 2, EPA ID Number OHR000654321
Site ID Section 9.A.2, Reporting-Year Status LQG because one month exceeded 2,200 pounds
Site ID Section 9.A.1, Current Status SQG, his normal monthly status
GM Form Section 1, Waste and Codes Solvent waste from tank cleanout, code F005
GM Form Section 2, Box B, Quantity Generated 2,900 pounds in the single event month
GM Form Section 3, Management Method Code H020 for solvent recovery, receiving facility EPA ID
Site ID Comments Notes the one-time event and that he did not opt into episodic rules
OI Form, Transporter and Facility Recovery facility name and EPA ID
Site ID Section 12, Certification Signed by Marcus Reed, proprietor

Scenario 3: Aisha Bello, environmental consultant filing for a client through eDRUMS

Form Section What Aisha Enters
Access role Logs in as a delegated preparer, not the RO
Site ID Section 1, Reason for Submittal “X” in report box, year 2025
Site ID Section 2, EPA ID Number Client’s OHD000789012
Site ID Section 7, Site Contact Client’s facility contact, not herself
GM Form Section 1, Waste and Codes Ignitable paint waste, code D001
GM Form Section 2, Box B, Quantity Generated 14,200 pounds
GM Form Section 3, Management Method Pre-populated receiving facility from eDRUMS pick list
OI Form Auto-populated by eDRUMS from GM Form entries
Report copy Copies prior-year report as the starting template
Site ID Section 12, Certification Sent to client’s RO to certify with a PIN

These cases show three more named filers in action beyond the walkthrough: Marcus Reed the proprietor, Aisha Bello the consultant, and David Chen the certifying officer. They also show the most useful eDRUMS features, such as the pick list and the auto-populated OI Form, that cut down on the typing errors paper filers make.

How to File the Completed Report

You can file electronically or on paper, and Ohio EPA prefers electronic submission through eDRUMS. Each channel has its own steps, address, and proof of filing, so pick one and follow it through to certification.

  • Electronic filing through eDRUMS. Submit inside Ohio EPA’s eBusiness Center after creating an OH|ID account; there is no fee to set up an account, the RO or DRO certifies with a PIN, and the certifier receives an immediate confirmation e-mail that serves as proof of filing.
  • Paper filing by U.S. Mail. Send the signed original to Ohio EPA – DERR, Hazardous Waste Information Management Section, P.O. Box 1049, Columbus, OH 43216-1049; there is no filing fee, and Ohio EPA recommends certified mail so the returned green card is your proof of filing.
  • Paper filing by overnight courier. Send to Ohio EPA – DERR, Hazardous Waste Information Management Section, Lazarus Government Center, 50 West Town Street, Suite 700, Columbus, OH 43215; keep the courier tracking record as proof of delivery by the deadline.

The deadline is firm. Reports are due by March 1, and if March 1 falls on a Saturday or Sunday, the due date moves to the following Monday. A paper report must be received by Ohio EPA by the end of the day on the deadline, not merely postmarked, so a last-minute mailing can arrive late and count as missed. There is no fee for the report itself, and the only accepted “payment” is your time and accurate data.

Two filing rules protect you from a false compliance flag. Do not mail your Right-to-Know (Tier II) report and your Hazardous Waste Report in the same envelope, because different divisions handle them and a misrouted report can make your site look out of compliance. Also, never mail the report to a district office, because the program is run only out of the Central Office in Columbus.

What Happens After You File

After you submit, Ohio EPA’s DERR enters your data into its database and forwards it to U.S. EPA to satisfy the federal biennial report requirement. This is why you only file once: the state handles the federal hand-off, and you never send a second report to U.S. EPA. If you filed in eDRUMS, the certifier already has an immediate confirmation e-mail showing the report is in.

Ohio EPA staff review the report for errors and may contact your listed Site Contact if a waste code, quantity, or EPA ID does not validate. This is the moment your recordkeeping pays off, because you must keep a copy of the report for at least three years, and inspectors will ask to see it along with your manifests. Filing the report also satisfies the every-two-year LQG re-notification duty under OAC 3745-52-18, so a clean filing keeps your RCRAInfo status current.

If you find a mistake after filing, you can amend the report. For paper filings, send a short cover letter with the new or corrected page, give the page a fresh unique page number, and for data corrections strike out the old value and write the new one in colored ink. For eDRUMS reports, you can usually e-mail the correction, and for extensive fixes you ask DERR report support to reopen the report in Edit mode so you can correct it yourself.

Mistakes to Avoid When Filling Out the Report

  • Entering the filing year instead of the reporting year in Site ID Section 1, which lands your data in the wrong period and can look like a missed report.
  • Transposing characters in the 12-character EPA ID, which attaches your waste data to the wrong site.
  • Marking the same status in Site ID Sections 9.A.1 and 9.A.2 by reflex, which can misstate your current standing in RCRAInfo.
  • Reporting only shipped waste in the GM Form instead of total quantity generated, which undercounts generation and can misstate LQG status.
  • Using a retired management method code such as H135, which fails validation and forces a correction.
  • Listing PCBs, asbestos, or state-only wastes that are not mixed with a RCRA waste, which puts non-RCRA data on a RCRA report.
  • Assuming a manifested material belongs on the report, which adds wastes that carry no federal RCRA codes.
  • Filing a separate OI Form for every GM Form, which creates redundant entries and raises the chance of an EPA ID mismatch.
  • Letting a consultant or preparer sign the certification without written authorization, which makes the report invalid.
  • Mailing the report so it is only postmarked by March 1 rather than received, which counts as a late filing because no extension is granted.
  • Putting the Hazardous Waste Report and the Right-to-Know report in the same envelope, which can misroute your filing and create a false compliance flag.
  • Sending the report to a district office instead of the Columbus Central Office, which delays processing.
  • Skipping the three-year recordkeeping copy, which leaves you unable to produce the report during an inspection.

Do’s and Don’ts

Do:

  • Do confirm your EPA ID against your RCRAInfo record before entering it, because a single wrong digit breaks the link between your forms.
  • Do file through eDRUMS when you can, because built-in validation catches code and math errors before submission.
  • Do report total quantity generated in GM Section 2, Box B, because that is what determines your generator status.
  • Do set up your OH|ID and eBusiness Center PIN weeks early, because account approval takes time.
  • Do keep a full copy of the filed report for at least three years, because inspectors will request it.
  • Do use the Comments section to explain any unusual circumstance, because it heads off a follow-up call from the state.

Don’t:

  • Don’t fax the report, because a fax lacks the original wet-ink signature the state requires.
  • Don’t equate shipment with generation, because status is based on monthly generation, not shipping dates.
  • Don’t use U.S. EPA’s federal forms in place of Ohio’s, because the forms differ and it causes data-entry problems.
  • Don’t enter a NAICS code of four digits or fewer, because it is too general for the state’s analysis.
  • Don’t list waste oil, PCBs, or asbestos unless they are mixed with a RCRA waste, because they are not RCRA-regulated alone.
  • Don’t wait until late February to file on paper, because the report must be received, not postmarked, by March 1.

Pros and Cons of Filing on Your Own vs. With Professional Help

Filing on Your Own (In-House) Filing With a Consultant
Pro: No consulting fee, which keeps costs down for a site with simple, steady waste streams. Pro: A consultant knows the waste codes and management method codes, which reduces validation errors.
Pro: Your staff knows the site’s processes firsthand, which speeds accurate waste descriptions. Pro: A consultant can be delegated as a preparer in eDRUMS, so they do the data entry while your RO simply certifies.
Pro: Copying last cycle’s eDRUMS report makes a repeat filing fast when streams do not change. Pro: Helpful for complex sites with many waste streams, on-site treatment, or trade-secret claims.
Con: You bear the full risk of a wrong code or missed deadline, which can draw enforcement. Con: There is a fee, which may not be worth it for a small, simple LQG.
Con: Without filing experience, you may misread the two generator-status boxes in Section 9. Con: You must still gather records and provide an authorized RO to certify, so you cannot fully hand it off.

FAQs

Does my paper report have to be received by March 1, or just postmarked by then?

Yes, it must be received by Ohio EPA by the end of the day on March 1, not just postmarked, per OAC 3745-52-41. If March 1 is a weekend, the due date is the next Monday.

Do I have to file a separate biennial report with U.S. EPA?

No. Ohio EPA forwards your data to U.S. EPA, so the only report you ever submit is the Ohio one using Ohio’s forms.

Can I get an extension to the March 1 deadline?

No. Ohio EPA grants no extension to the March 1 submittal deadline under any circumstances, so plan to file early.

Can I fax the report to Ohio EPA?

No. Faxed reports are not accepted because they lack the original wet-ink signature required on paper filings.

Can I use U.S. EPA’s federal biennial report forms instead of Ohio’s?

No. DERR discourages federal forms because they are not identical to Ohio’s and cause data-entry and review problems.

Do I write the filing year or the reporting year in Site ID Section 1?

No, not the filing year. You write the reporting year the activity happened, so a 2026 filing covering 2025 waste shows 2025 in the year blank.

Should Section 9.A.1 and Section 9.A.2 always show the same generator status?

No. Section 9.A.1 is your current status and 9.A.2 is your reporting-year status, and they can differ after a one-time LQG event.

Do I count waste I generated but had not shipped by December 31?

Yes. Report the full quantity generated in GM Section 2, Box B, and list only the shipped portion in Section 3.

Do I need a separate OI Form for each GM Form?

No. One OI Form serves all GM Forms because the data links through EPA ID numbers, and each OI Form holds up to four facilities.

Should I list waste oil, PCBs, or asbestos on the report?

No, not unless they are mixed with a RCRA-regulated waste, in which case you follow the Special Instructions in the booklet.

If a one-time event made me generate over 2,200 pounds in a month, must I file?

Yes, unless you opted into the episodic generator rules by submitting the Episodic Generator Addendum and Site ID Form before the event.

Who is allowed to sign the certification on the Site ID Form?

Yes, only certain people may sign per OAC 3745-50-42: a corporate officer, general partner, proprietor, principal executive, or an authorized written representative.

Can a consultant prepare my report in eDRUMS?

Yes. A consultant can be delegated as a preparer with an eBusiness Center account, but only the RO or DRO with a PIN can certify it.

Do SQGs and VSQGs have to file this report?

No, not normally, unless a one-time event pushed them over the LQG threshold in a month and they did not opt into the episodic rules.

Is there a fee to file the Biennial Hazardous Waste Report?

No. There is no filing fee for the report and no charge to set up an eBusiness Center account for electronic filing.