How to Fill Out the Pennsylvania DEP NPDES Industrial Stormwater Permit (PAG-03 NOI) + FAQs

The Pennsylvania DEP NPDES Industrial Stormwater Permit is the legal authorization that lets a factory, scrap yard, landfill, or other industrial site discharge rainwater runoff into rivers, streams, and storm sewers. Most facilities get this coverage by filing a Notice of Intent (NOI) under the PAG-03 General Permit, form number 3800-PM-BCW0083, which the Pennsylvania Department of Environmental Protection (DEP) reissued for a five-year term that became effective March 24, 2023.

If you skip this permit or fill it out wrong, you are not just risking a paperwork delay. You are discharging pollutants into waters of the Commonwealth without authority, which is a violation of both the federal Clean Water Act and Pennsylvania’s Clean Streams Law. DEP processes thousands of these filings, and a single missed appendix, a forgotten Preparedness, Prevention, and Contingency (PPC) Plan, or a late annual fee can stall your coverage for months. This guide walks you through the form line by line, in plain language, so you can file with confidence.

Here is what you will learn in this guide:

  • 📋 What the PAG-03 NOI is, who must file it, and how it differs from an individual permit and No Exposure Certification
  • 🗂️ The exact documents, data, and ID numbers you must gather before you open the form
  • ✍️ A line-by-line walkthrough of every section, with sample entries you can copy
  • 💵 The fees, deadlines, and penalties that govern your filing and renewal
  • ⚠️ The most common mistakes that get NOIs rejected and how to avoid each one

What the Form Is and Who Must File It

The PAG-03 NOI is a request to the DEP for coverage under a single, statewide general permit that authorizes discharges of stormwater associated with industrial activity. Instead of writing a custom permit for every plant, DEP wrote one set of rules in the PAG-03 General Permit and lets eligible facilities “opt in” by filing the NOI. The federal regulations at 40 CFR 122.26 name the specific classes of industrial facilities that must obtain NPDES permit coverage, and DEP can also require coverage for any other facility it finds is discharging pollutants to waters of the Commonwealth.

You must file if your facility falls into one of the regulated industrial categories and rain or snowmelt that touches your industrial materials or activities then flows off your property. Typical filers include manufacturers, landfills, scrap and recycling yards, transportation terminals, and bus depots, as SCS Engineers explains. The plain-English version is simple: if rain hits your raw materials, machinery, fueling areas, or waste and then runs off-site, you almost certainly need this permit.

The form matters because it ties together five things at once. The purpose is to control pollution in runoff. The agency that receives it is the DEP regional office for your county. The statute behind it is the Clean Streams Law working alongside the federal Clean Water Act. The deadline is set by your facility’s start date or your existing permit’s terms. The penalty for ignoring it includes fines, enforcement orders, and personal liability for the certifying official. Each piece depends on the others, so getting the form right protects you on all five fronts.

Three filing paths exist, and you choose your path on the same NOI form. You can seek PAG-03 General Permit coverage, you can apply for an Individual NPDES Permit using form 3800-PM-BCW0403 if you are not eligible, or you can request a No Exposure Certification (NEC) if all industrial materials and activities are kept indoors or under roof. A common reason a facility cannot use PAG-03 is that it sits in a High Quality or Exceptional Value watershed under Chapter 93, which forces it onto the individual permit track.

Before You Start: Documents and Information You Need

Gather everything below before you open the NOI. Filing with missing data is the top reason coverage gets delayed, because DEP cannot process an incomplete package and will return it to you. Think of this as your pre-flight checklist.

  • Facility name, address, and county. This determines which of the six DEP regional offices reviews your filing; the wrong office means lost time while it gets rerouted.
  • Standard Industrial Classification (SIC) code. Your SIC code maps your facility to the correct PAG-03 appendix and monitoring set; pick the wrong one and your monitoring plan will not match your sector.
  • Client and Site IDs from DEP’s eFACTS system. These link your filing to your facility record; missing IDs slow matching and can create duplicate records.
  • The legal name and signature authority of your responsible official. The certification must be signed by a person with legal authority, or DEP rejects the NOI as improperly executed.
  • Receiving water name and watershed information. You must name the stream or storm sewer that receives your discharge so DEP can check its designated use and chapter classification.
  • A site map and outfall locations. You need latitude and longitude for each discharge point; vague locations trigger requests for more information.
  • Your Preparedness, Prevention, and Contingency (PPC) Plan. The PAG-03 General Permit requires you to prepare and maintain this plan, as ALL4 confirms; filing without it on hand means you cannot certify compliance honestly.
  • Two years of analytical monitoring data, if you have an existing discharge. This data supports your eligibility and benchmark comparisons; without it, DEP cannot confirm your discharge meets the appendix limits.
  • Your NOI fee payment. New applicants must include the fee, and online filers must pay through DEP’s portal; an unpaid fee stops the clock entirely.

Each item carries weight. If your SIC code is missing, you cannot select the right appendix, and the entire monitoring section falls apart. If your PPC Plan does not exist, the certification you sign becomes false, which is a separate violation on top of the permit issue. Treat this list as mandatory, not optional.

Where to Get the Form and How to Access It

The official PAG-03 NOI and its instructions live in DEP’s eLibrary under form number 3800-PM-BCW0083. You can pull the NOI package from GreenPort, which bundles the Notice of Intent, the detailed NOI Instructions (3850-PM-BCW0083a), the General Permit text, the sector appendices, and the fact sheet. Always download the current version rather than reusing an old saved copy, because the reissued permit changed monitoring rules.

Confirm you have the right revision before you write anything. The version tied to the permit reissued effective March 24, 2023 is the one to use, since Eckert Seamans reported the new five-year term and the March 23, 2023 deadline for existing permittees. Using an outdated form risks missing the new Total Nitrogen and Total Phosphorus monitoring that DEP added to every appendix.

You can complete the form two ways. The first is the fillable PDF you download, print, and mail. The second is the online route through DEP’s Public Upload platform, where DEP now accepts permit applications and fees electronically. DEP states that if a fee is required, it must be paid online when you use the upload platform, so plan to have a payment method ready before you start the electronic version.

Read the NOI Instructions document side by side with the form. Table 1 of the NOI Instructions identifies the PAG-03 appendices, the matching SIC codes, and the industrial sectors, so it acts as your decoder ring for the rest of the form. Keep it open the whole time you fill out the monitoring and eligibility sections.

Step-by-Step: How to Fill Out the PAG-03 NOI Line by Line

This section is the heart of the guide. Work through it in the order the fields appear on form 3800-PM-BCW0083. Each field gets its own walkthrough so you never have to guess.

Section A, Field 1: Application Type

What it asks in plain English. This field wants to know why you are filing: a brand-new request, a renewal of existing coverage, an amendment, or a transfer to a new owner.

How to answer it. Check the single box that matches your situation. For a first-time filer, mark New. For an existing permittee keeping coverage alive, mark Renewal. Do not check more than one box.

A specific example answer. Marcus runs a new metal-fabrication shop in Allentown seeking coverage for the first time, so he checks New.

A nuance or edge case. If you bought a facility that already holds PAG-03 coverage, you mark Transfer rather than New, because the existing authorization moves with the site.

A common mistake and its consequence. Filers often mark New when they should mark Renewal, which can create a duplicate facility record and trigger a second fee that you do not owe.

A misconception about this field. Many people think a renewal lets them skip the rest of the form; in truth, you still complete every section because DEP re-reviews your eligibility each term.

Section A, Field 2: Permit and Authorization Numbers

What it asks in plain English. This field captures any existing PAG-03 permit number and authorization number if you have one.

How to answer it. Enter your existing number exactly as it appears on your prior authorization, including the PAG03 prefix and the numeric string. New filers leave this blank.

A specific example answer. An existing permittee writes PAG038000 followed by its assigned digits, copied character-for-character from its last authorization letter.

A nuance or edge case. If you cannot locate your number, look it up in DEP’s eFACTS or call the Division of NPDES Permitting at 717-787-5017 before guessing.

A common mistake and its consequence. Transposing two digits links your NOI to the wrong facility, which can apply someone else’s monitoring history to your file.

A misconception about this field. People assume a blank here will be filled in by DEP; for renewals it will not, and a missing number can be read as a new application.

Section B: Facility Information

What it asks in plain English. This block asks for the facility’s legal name, the physical street address, the municipality, the county, and the contact person on site.

How to answer it. Write the facility’s legal operating name, not a nickname, and use the physical street address where the industrial activity happens, not a billing address. Spell out the county fully.

A specific example answer. Marcus enters Lehigh Valley Metalworks LLC, 1450 Industrial Drive, Allentown, municipality City of Allentown, county Lehigh.

A nuance or edge case. If your site has no street number because it is a rural parcel, provide the route and a clear physical description plus coordinates so the inspector can find it.

A common mistake and its consequence. Using a corporate headquarters address instead of the plant address sends DEP staff to the wrong location and routes your file to the wrong regional office.

A misconception about this field. Filers believe the mailing address and facility address must match; they often differ, and DEP collects both for that reason.

Section C: Client (Applicant) Information

What it asks in plain English. This field identifies the legal entity that owns or operates the facility, along with its DEP Client ID.

How to answer it. Enter the exact legal name of the company, its mailing address, and the eFACTS Client ID if one exists. Match the name to your corporate registration.

A specific example answer. The applicant line reads Lehigh Valley Metalworks LLC, with Client ID pulled from DEP’s eFACTS lookup.

A nuance or edge case. If a parent company owns the plant but a subsidiary operates it, list the operator as the client, because the operator controls compliance day to day.

A common mistake and its consequence. Listing a “doing business as” trade name instead of the registered legal entity can void the certification, since the signing official represents the legal entity.

A misconception about this field. People think the client and the facility are always the same record; DEP treats them separately so one company can hold many sites.

Section D: Standard Industrial Classification and Appendix Selection

What it asks in plain English. This field asks which industrial sector you fall under and, by extension, which PAG-03 appendix controls your monitoring.

How to answer it. Enter your primary four-digit SIC code, then use Table 1 in the NOI Instructions to find the matching appendix letter. Record that appendix on the form.

A specific example answer. Marcus enters SIC 3444 for sheet metal work and selects the matching fabricated-metal appendix shown in Table 1.

A nuance or edge case. If your site spans two industrial activities, you may need to satisfy more than one appendix, so check every applicable row, not just your main one.

A common mistake and its consequence. Choosing an appendix that does not match your SIC code means you will monitor the wrong pollutants, and DEP can find you out of compliance even though you tested something.

A misconception about this field. Filers assume the appendix only sets a few tests; in fact, the reissued permit added Total Nitrogen and Total Phosphorus to every appendix, as Trinity Consultants notes.

Section E: Receiving Waters and Discharge Points

What it asks in plain English. This field asks where your stormwater goes and the exact location of each outfall.

How to answer it. Name the receiving stream or storm sewer, list each outfall with its latitude and longitude in decimal degrees, and attach a site map showing the points. Use MM/DD/YYYY for any dates.

A specific example answer. The form shows Outfall 001, Little Lehigh Creek, 40.5934 N, 75.4902 W, drawn on the attached map.

A nuance or edge case. If your runoff enters a municipal storm sewer (MS4) rather than a stream, name the MS4 operator and the ultimate receiving water both.

A common mistake and its consequence. Reporting only one outfall when the site has several hides part of your discharge, which is a misrepresentation that can trigger enforcement later.

A misconception about this field. People think a storm sewer is not “waters of the Commonwealth”; the discharge still reaches a regulated water, so it counts.

Section F: Eligibility and Watershed Screening

What it asks in plain English. This field confirms your facility is eligible for the general permit and not located where the permit is barred.

How to answer it. Answer the eligibility questions honestly, confirming you are not in a High Quality or Exceptional Value watershed and that you meet the permit’s screening conditions.

A specific example answer. Marcus checks No to the High Quality or Exceptional Value watershed question after confirming Little Lehigh Creek’s classification under Chapter 93.

A nuance or edge case. If you discover your stream is High Quality or Exceptional Value, stop and switch to the Individual NPDES Permit application, because PAG-03 is not available to you.

A common mistake and its consequence. Guessing at your watershed classification can put you on the wrong permit track entirely, wasting the fee and months of review time.

A misconception about this field. Filers think eligibility is a formality; it is the gate that decides whether the whole general-permit path is even open to you.

Section G: No Exposure Certification Election (If Applicable)

What it asks in plain English. This field lets a qualifying facility certify that all industrial materials and activities are kept indoors or under roof, avoiding the need for monitoring.

How to answer it. Select the No Exposure Certification box only if you truly keep everything covered, then complete the supporting certification. The NOI fee still applies, and the NEC must be renewed every five years.

A specific example answer. Janet manages a small electronics assembler where every material sits indoors, so she elects No Exposure Certification and pays the required NOI fee.

A nuance or edge case. Even one uncovered dumpster of scrap can disqualify you from NEC, so inventory every outdoor item before you certify.

A common mistake and its consequence. Claiming no exposure while leaving materials outside is a false certification, which exposes the signer to enforcement and penalties.

A misconception about this field. People think NEC is permanent; it expires every five years and is not available in High Quality or Exceptional Value watersheds.

Section H: Preparedness, Prevention, and Contingency (PPC) Plan Confirmation

What it asks in plain English. This field confirms you have prepared and will maintain a PPC Plan that addresses spills, leaks, and pollution prevention.

How to answer it. Confirm the plan exists and covers your material inventory, spill prevention, countermeasures, and an emergency spill control network, as August Mack describes. Keep the plan on site.

A specific example answer. Marcus confirms his PPC Plan lists his solvent drums, his spill kits, and his emergency contacts, and he keeps it in the plant office.

A nuance or edge case. If you also store more than 1,320 gallons of oil, you likely need a separate SPCC plan, and experts recommend keeping it apart from the PPC Plan.

A common mistake and its consequence. Confirming a PPC Plan you have not written is a false statement, and inspectors routinely ask to see the plan during site visits.

A misconception about this field. Many believe the PPC Plan must be certified by a Professional Engineer; the general permit removed that requirement for most filers.

Section I: Certification and Signature

What it asks in plain English. This final block is the legal certification where a responsible official swears the information is true and signs.

How to answer it. The signature must come from a person with legal signing authority for the entity, such as a corporate officer or a designated facility manager. Date it MM/DD/YYYY.

A specific example answer. Marcus Reyes, Managing Member, signs and dates the certification 06/15/2026.

A nuance or edge case. A consultant who prepared the form cannot sign the certification unless the company has formally delegated that authority in writing.

A common mistake and its consequence. An unauthorized signature makes the NOI improperly executed, and DEP can reject the entire filing on that basis alone.

A misconception about this field. People think the certification is routine boilerplate; it carries personal liability, because knowingly false statements can lead to fines and even criminal exposure.

Three Filled-Out Examples Using Real Scenarios

These three walkthroughs show how different facilities complete the same form. Each follows one named filer from start to finish.

Scenario 1: Marcus, a new metal-fabrication shop seeking first-time coverage.

Form Section What Marcus Enters
Application Type New
Permit/Authorization Number Left blank (no prior coverage)
Facility Name and Address Lehigh Valley Metalworks LLC, 1450 Industrial Drive, Allentown
County Lehigh
SIC Code and Appendix 3444, matched to the fabricated-metal appendix
Receiving Water and Outfall Outfall 001, Little Lehigh Creek, 40.5934 N, 75.4902 W
Eligibility Screening No to High Quality/Exceptional Value watershed
PPC Plan Confirmation Yes, plan prepared and kept on site
Certification Marcus Reyes, Managing Member, 06/15/2026

Scenario 2: Priya, an existing landfill operator renewing coverage.

Form Section What Priya Enters
Application Type Renewal
Permit/Authorization Number PAG03 plus existing assigned digits
Facility Name and Address Keystone Regional Landfill, 88 Ridge Road, Greensburg
County Westmoreland
SIC Code and Appendix 4953, matched to the landfill appendix
Receiving Water and Outfall Outfall 001 and 002, Sewickley Creek, with coordinates
Monitoring Data Two years of analytical results attached
PPC Plan Confirmation Yes, updated plan on file
Certification Priya Nair, Environmental Manager, 02/20/2026

Scenario 3: Janet, a small electronics assembler electing No Exposure Certification.

Form Section What Janet Enters
Application Type New
NEC Election Yes, No Exposure Certification selected
Facility Name and Address Quartz Circuits Inc., 12 Commerce Court, Lancaster
County Lancaster
SIC Code 3672, printed circuit boards
Exposure Statement All materials and activities indoors/under roof
Watershed Screening No to High Quality/Exceptional Value
NOI Fee Paid online with the filing
Certification Janet Cho, President, 04/10/2026

Each filer touches the same form differently, but all three sign the same binding certification. Aisha, a consultant helping a fourth client, would prepare any of these but could not sign unless her client delegated authority in writing.

How to File the Completed Form

You can file through two main channels, and DEP now leans toward electronic submission. Choose the one that fits your workflow, but keep proof of filing either way.

Online (preferred). Submit through DEP’s Public Upload platform, where you upload the NOI and pay the fee electronically. DEP states that required fees must be paid online when you use this route. Save the confirmation page and any transaction receipt as your proof of filing.

By mail. Print the completed NOI, attach your site map and supporting documents, include a check for the fee, and mail it to the DEP regional office that serves your facility’s county. Your county determines which of the six regional offices receives the package, so confirm the correct address in the NOI Instructions before you send it. Use certified mail with a return receipt so you have dated proof.

For fees, the NOI fee is $500, and that same $500 applies to those seeking No Exposure Certification, as stated in the NOI Instructions. Accepted payment methods are online electronic payment through the portal or a check or money order by mail made payable as the instructions direct. Processing time varies by regional office workload, so file well ahead of any deadline rather than at the last minute.

Keep a complete copy of everything you submit. Retain the signed NOI, the site map, the PPC Plan, your monitoring data, and your payment receipt together in one file. If DEP ever questions your coverage, this packet is your evidence that you filed correctly and on time.

What Happens After You File

After you submit, DEP’s regional office reviews your NOI for completeness and eligibility. If the package is complete and you qualify, DEP issues an acknowledgment or authorization that confirms your coverage under the PAG-03 General Permit. Coverage generally runs for the permit term, which ends March 23, 2028 for the current cycle.

If something is missing, DEP sends a request for additional information, and your review clock pauses until you respond. This is why a complete first submission matters so much. A facility that left out its outfall coordinates or its appendix selection will wait while it gathers and resends the missing piece.

Once covered, you take on ongoing duties. You must perform the monitoring set by your appendix, including the Total Nitrogen and Total Phosphorus parameters DEP added to every sector, and you report results through eDMR. DEP has stated that the new nitrogen and phosphorus requirements were added automatically to existing permittees’ eDMRs, so check that your parameters match your appendix and contact RA-EPDMR@pa.gov if they do not.

You also owe annual obligations. Beginning in 2024, the annual report and the annual NOI installment fee became due by March 23 each year, as Liberty Environmental reported. Missing these annual steps can put you out of compliance even though your original NOI was perfect, so calendar the date now.

Mistakes to Avoid When Filling Out the Form

Form errors cause most PAG-03 delays. Each mistake below has a direct, specific consequence.

  • Choosing the wrong application type creates duplicate records and can charge you a fee you do not owe.
  • Entering a wrong permit number links your file to another facility’s history.
  • Using a billing address instead of the plant address routes your NOI to the wrong regional office.
  • Listing a trade name instead of the legal entity can void your certification.
  • Picking a SIC code that does not match your activity puts you on the wrong appendix and wrong monitoring set.
  • Skipping the Total Nitrogen and Total Phosphorus parameters leaves you out of compliance with the reissued permit.
  • Reporting only one outfall when you have several misrepresents your discharge and invites enforcement.
  • Guessing your watershed classification can wrongly keep you on PAG-03 when you needed an individual permit.
  • Certifying no exposure while storing materials outdoors is a false statement that triggers penalties.
  • Confirming a PPC Plan you never wrote fails inspection the moment DEP asks to see it.
  • Signing without legal authority makes the NOI improperly executed and subject to rejection.
  • Forgetting the $500 fee, or paying by the wrong method, stops your review before it starts.

Do’s and Don’ts

Do:

  • Do download the current 3800-PM-BCW0083 form, because the reissued permit changed monitoring rules.
  • Do read Table 1 of the NOI Instructions, since it links your SIC code to the right appendix.
  • Do gather two years of monitoring data first, because DEP uses it to confirm eligibility.
  • Do keep your PPC Plan on site, since inspectors routinely ask to see it.
  • Do file electronically through Public Upload, because DEP now prefers and speeds online submissions.
  • Do save your confirmation and receipt, since they are your proof of timely filing.

Don’t:

  • Don’t reuse an old saved PDF, because an outdated form omits required parameters.
  • Don’t guess your watershed status, since the wrong call sends you down the wrong permit path.
  • Don’t let a consultant sign without written authority, because that voids the certification.
  • Don’t elect No Exposure Certification if anything sits outdoors, since that is a false statement.
  • Don’t miss the March 23 annual deadline, because late fees and reports break your compliance.
  • Don’t mail without certified tracking, since you need dated proof of submission.

Pros and Cons of Filing on Your Own vs. With Help

Deciding whether to file yourself or hire a consultant depends on your facility’s complexity and your in-house expertise.

Pros of filing on your own:

  • You save the consultant fee, which matters for a small single-outfall site.
  • You learn your own permit, which helps you manage ongoing monitoring.
  • You control the timeline directly without waiting on an outside firm.
  • You keep sensitive site data in house.
  • You build a direct relationship with your DEP regional office.

Cons of filing on your own:

  • You may pick the wrong appendix without sector experience, causing compliance gaps.
  • You carry full personal liability on the certification you sign.
  • You may misread watershed classifications and choose the wrong permit track.
  • You can underestimate the PPC Plan and monitoring workload.
  • You have no expert to catch errors before DEP does, risking delay.

Comparing Your Three Permit Pathways

This table shows how the three coverage options differ so you can confirm you are on the right track.

Pathway When It Fits
PAG-03 General Permit (NOI) Eligible industrial site with exposed activities, not in a High Quality or Exceptional Value watershed
Individual NPDES Permit (3800-PM-BCW0403) Facility ineligible for PAG-03, often due to a High Quality or Exceptional Value watershed
No Exposure Certification (NEC) Qualifying site that keeps all materials and activities indoors or under roof, renewed every five years

The key agencies and rules that interact with this form include the DEP Bureau of Clean Water’s Division of NPDES Permitting, which oversees the program; the U.S. EPA, which runs the federal NPDES framework under the Clean Water Act; and the Pennsylvania Clean Streams Law, which makes unpermitted discharges to waters of the Commonwealth illegal. Chapter 93 designated uses decide your watershed classification, and the PPC Plan rules tie your stormwater permit to spill prevention duties. Each one shapes how you complete and maintain the NOI.

FAQs

Do I need a PAG-03 permit if rain touches my outdoor materials?

Yes. If runoff contacts your industrial materials, machinery, or waste and then leaves your site, you fall under the program and must seek coverage or qualify for No Exposure Certification.

Do I file the same form for general permit coverage and No Exposure Certification?

Yes. You use the PAG-03 NOI for both and select the No Exposure Certification election within the form, and the $500 NOI fee applies to NEC requests too.

Do I write my trade name or legal entity name in the Client section?

No. Enter the registered legal entity that owns or operates the facility, because the certification binds that legal entity and a trade name can void it.

Do I enter my headquarters address in the Facility section?

No. Enter the physical plant address where the industrial activity happens, since your county there decides which DEP regional office reviews your filing.

Do I pick the appendix or does DEP pick it for me?

No. You select the appendix using your SIC code and Table 1 of the NOI Instructions, and choosing the wrong one puts you on the wrong monitoring set.

Do I need to report every outfall, even small ones?

Yes. List each discharge point with its coordinates, because omitting outfalls misrepresents your discharge and can lead to enforcement.

Do I need a PPC Plan before I file?

Yes. The PAG-03 General Permit requires you to prepare and maintain a PPC Plan, and confirming one you have not written is a false statement.

Do I need a Professional Engineer to certify my PPC Plan?

No. The general permit removed the PE certification requirement for most filers, though some individual permits still require it.

Do I have to monitor for Total Nitrogen and Total Phosphorus?

Yes. The reissued PAG-03 added these parameters to every appendix, so check that your eDMR matches your sector and email RA-EPDMR@pa.gov if it does not.

Do existing permittees pay a fee with the renewal NOI?

No. Existing holders did not submit a fee with the renewal NOI, but the annual NOI installment fee became due by March 23 starting in 2024.

Do I qualify for PAG-03 if my stream is High Quality or Exceptional Value?

No. Those watersheds bar PAG-03 and No Exposure Certification, so you must apply for an Individual NPDES Permit using form 3800-PM-BCW0403.

Do I have to renew No Exposure Certification?

Yes. No Exposure Certification expires and must be renewed every five years, and it stays unavailable in High Quality or Exceptional Value watersheds.

Do I have to file online, or can I mail the form?

No. You are not forced online, but DEP now prefers electronic submission through Public Upload and requires online payment when you use that platform.

Do I keep proof after I file?

Yes. Save your confirmation, receipt, and a full copy of the NOI and attachments, because that packet is your evidence of timely, correct filing.